ALGcom FN-4800-25-SNMP-X
- SKU: FN-4800-25-SNMP-X
$938.93
+ $267.50 Tariff
Product Information
ALGcom DC UPS 48V 25A Manageable SNMP (w/ dry contacts)
Specifications
Specifications
| Weight | 2.5 lbs |
| Dimensions (L x W x H) | 1.80” x 17.5” x 10” 45x440x250mm/3.80kg |
| Nominal Input Voltage | 100 – 240 VAC |
| Input Voltage Range | 100 – 270 VAC |
| Frequency | 50/60 Hz |
| Input Current | 14.67 ARMS / 6.11 ARMS (100/240 VAC) |
| Protections | Two 15 A circuit breakers for short- circuit and overload protection, one for the Line and another for the Neutral |
| Protections | Varistor: 300 VAC, 170 J varistor for protection against lightning and electrical surges |
| Undervoltage: Disconnects the AC-DC converter if voltage <100 VAC | |
| Overvoltage: Disconnects the AC-DC converter if voltage >270 VAC | |
| Output Characteristics | FN-4800-25 ST/SNMP/SNMP-X |
| Nominal Output Voltage | 54 VDC |
| Output Voltage Range | 42 - 58 VDC |
| Maximum Output Current | 25 A |
| Maximum Output Power | 1450 W |
| Adjustable Battery Charging Current | 1/5/10/15 A Via Selector Switch; 1 - 15 A Via Web Page (SNMP) |
| Battery Fuse for short- circuit and overload protection | 25 A |
| Short Circuit | Short-circuit current <5 A with automatic rearming |
| Overcurrent | Limits the output current to the nominal value of 26.5 A |
| Derating | Limits the output current to 15 A in case of ventilation failure |
| Limits the output current to 15 A if the internal temperature of the heat exchangers is above 75°C " | |
| Limits the output current to 20 A if the input voltage is below 110 VAC | |
| Overvoltage | Disconnects the AC-DC converter if the output voltage is >60 VDC |
| Battery Undervoltage | Disconnects the battery bank if the voltage is lower than the configured voltage (Default voltage 42 VDC) |
| Overtemperature | Disconnects the AC-DC converter if the temperature > 80°C and reconnects at 70°C |
| General Specifications | FN-4800-25 ST/SNMP/SNMP-X |
| Power Factor (Rated Load) | 0.98 / 0.98 (127/ 220 VAC) |
| Efficiency | >92 % (full load) |
| Line+Neutral Isolation for Output | 3000 VAC |
| Line+Neutral Isolation for Ground | 2500 VAC |
| Output Isolation for Ground | 1000 VAC |
| Operating Temperature | -10 ºC até 60 ºC |
| Operating Humidity | 20 a 90 % (non-condensing) |
| Alarm Red LED | Overtemperature, Overload, Ventilation Failure (Blinking) |
| Alarm Green LED | Battery Charging, Battery Discharging, and AC Power |
| Alarms Web Page (SNMP) | Minimum AC Input Voltage, Maximum AC Input Voltage, Overload, Overtemperature, Output Overvoltage, Ventilation Failure, Temperature Sensor Failure, Battery Charging, and Battery Discharging |
| Digital Inputs (SNMP-X) | 0 - 60 VDC (voltage greater than 5 VDC, logic level 1) |
| Digital Relay Output (SNMP-X) | 60 VDC 1 A |
| Installation Mode | 1 U height for 19" racks |