The connectors are designed according the standard interfaces as N female. Contact components are silver or trimetal plated to minimize insertion loss and passive intermodulation products; mechanical parts are nickel plated for heavy-duty handling and best corrosion resistance. Watertightness is achieved by using silicone o-rings to resist in the toughest environmental conditions. For a cost effective, easy and reliable installation, special trimming tools are recommended.
Features:
- Low reflection coefficient (up to 6 GHz)
- Low PIM level
- High contact force through inner contacts made in a high-strength copper alloy
- Watertight (IP67/IP68)
- Corrosion resistant
- Installation "fit on and tighten it"
- O-ring sealing
Specifications
Specifications NF50V12
| Electrical | |
| Nominal impedance [Ω] | 50 |
| Return loss @ 3 GHz [dB] | ≥ 35 |
| Insulation resistance [GΩ] | ≥ 5 |
| Test voltage (at sea level) [kV rms, 50Hz] | 2.5 |
| Working voltage (at sea level) [kV rms,50Hz] | 1 |
| Max. peak power [kW]* | 10 |
| Screening effectiveness up to 1 GHz [dB] | > 128 |
| Contact resistance (outer contact) [mΩ] | ≤ 1 |
| Contact resistance (inner contact) [mΩ] | ≤ 1 |
| PIM ratio (2 x 20 W carrier) [dBc] | ≤ -155 (Typical -163) |
| Mechanical | |
| Torque of coupling mechanism [Nm] | 3 to 5 |
| Tensile strength of coupling mechanism [N] | 400 |
| Cable retention [N] | > 500 |
| Mechanical endurance (Nr of couplings) | ≥ 500 |
| Outer diameter [mm] | 22 |
| Length [mm] | 59 |
| Weight [g] | 88 |
| Environmental | |
| Temperature range | -40 °C to +85 °C (-40 °F to +185 °F) |
| Degree of protection | IP67/IP68 (mated connectors) |
| Climatic & moisture resistance test | acc. ANSI/SCTE 72 2002 R2007 (-40 °C / +60 °C @ 75% r.h.) for 2 weeks |
| Corrosion resistance test | acc. IEC 60068-2-11-Test Ka |
| Vibration test | acc. IEC 60068-2-6 (10 to 500 Hz @ 10 G) |
| Materials | |
| Externals parts | Brass with passivated silver or trimetal or nickel plating |
| Outer contact | Brass with passivated silver or trimetal plating |
| Inner contact | Passivated silver plated high-strength copper alloy and brass |
| Dielectric | TPX / PTFE |
| O-rings | High quality silicone |
| Cable dimensions [mm] | |
| Inner conductor outer diameter | 4.75 to 4.85 |
| Outer conductor outer diameter | 13.6 to 13.9 |
| Jacket outer diameter | 15.6 to 16.4 |